Shielded Cat6 for CCTV: When Is It Worth Using?

Unshielded Cat6 is enough for most camera runs. Shielded cable helps near mains or electrical noise, but only if it is properly earthed.

Grey Cat6A solid core network cable on a 305 m reel

For most camera runs, unshielded Cat6 is enough. Shielded cable earns its place only where a run sits close to mains cabling, motors or other electrical noise, and only when the shield is properly connected to earth at the equipment. A shield that is not bonded properly does little, and one bonded badly can add a fault of its own. If you cannot be sure of the earthing, stay with unshielded cable.

What shielding does

An unshielded cable (U/UTP) relies on the twist of its pairs to reject interference. A shielded cable adds foil, braid or both. Cabling Installation & Maintenance describes shielded Category 6A cable as using foil and/or braided shielding, either as individual shields around each pair or as a single foil around all pairs. The screen only helps if it is connected to earth: Panduit's guide to shielded cabling systems says even the best components underperform if the shield is not properly terminated and grounded.

When shielded cable is worth it

  • Long runs alongside mains or power cables. Our shielded Cat6 patch lead is made for cable that runs alongside power cables or other sources of electrical interference.
  • Electrically noisy environments, which is what our Connectix F/FTP cable is made for.
  • Dense bundles of many network cables in one tray or duct, where shielded cable cuts crosstalk between neighbouring cables.

A typical house or small shop with a few cameras and a short route does not have these problems, and unshielded solid copper Cat6 does the job. Our Cat6 or Cat6a guide covers the rest of the choice.

Shielded cable we sell

Most of our shielded cable is Cat6a, plus one Cat6 patch lead. The Connectix TruLAN Cat6A F/FTP cable has foil-shielded pairs plus an overall foil screen and a polyethylene sheath for external and duct runs. The TruHD Cat6A U/FTP cable has a foil on each pair, a low smoke halogen-free jacket. It comes pre-terminated with RJ45 connectors and is not for field termination. For short patch connections between switch and recorder, the Cat6 SFTP patch cable is a stranded 26AWG shielded lead with a PVC jacket for indoor use. The unshielded choice for a normal run is our Cat6 U/UTP outdoor reel in 23AWG solid copper.

The connectors must be shielded too

A shielded cable ended in an ordinary plastic plug has a screen that goes nowhere. Use shielded plugs and jacks so the screen runs unbroken from one end to the other. We sell the Klein Tools VDV826-764 shielded pass-through plug, made for Cat6a and larger-diameter shielded Cat6, and a shielded Cat6a keystone jack for wall plates and patch panels. Browse the full range in Connectors. The plug has to suit the cable's diameter, so check both before ordering.

Earthing: get it right or skip the shield

Shielded cabling needs to be bonded to a proper earth. Cabling Installation & Maintenance explains that ground loops develop when there is a voltage difference between the earth at each end of a cable shield, so current flows through the shield. Panduit adds that grounding both ends is sometimes recommended but must be done properly to avoid ground loops. Earthing work belongs to a qualified electrician or installer. If the switch and the camera end cannot be bonded properly, unshielded cable is the safer choice.

Which to buy

  • Ordinary run, no noise source nearby: unshielded solid copper Cat6.
  • Noisy route or crowded duct, with earthing in place: shielded Cat6a with shielded plugs and jacks.
  • Not sure about the route or the earthing: ask us before ordering.

See every option in our Cat6 and Cat6A cable categories.

Parts named here

Frequently asked questions

Do I need shielded Cat6 for CCTV cameras?

Usually not. Choose shielded cable for runs beside mains cabling or electrical noise, and only if it can be earthed properly.

Can I use shielded cable with ordinary RJ45 plugs?

You can, but the screen is then broken at the plug. Use shielded plugs and jacks so the screen runs through.

What happens if shielded cable is not earthed properly?

The shield gives little protection, and a voltage difference between its two ends can cause a ground loop. Ask an electrician if unsure.

Sources & references